The shutdown revealed a much bigger problem than potential nozzle-head cracks: Davis-Besse's reactor head itself was so corroded that it was a mere two-tenths of an inch from blowing open. It was the worst corrosion in U.S. nuclear history.
NRC officials eventually labeled it the nation's biggest safety lapse since the Three Mile Island Unit 2 meltdown in Pennsylvania in 1979, in part because of doubts over whether emergency safety systems would have worked once radioactive steam had formed.
Rep. Dennis Kucinich (D., Cleveland), whose district is downwind from Davis-Besse, became so incensed that he tried to get FirstEnergy's operating license revoked.
[...]
He said the utility's history of mismanagement is one of the nation's most underrated stories. "It's all about money in the end. It's not about public safety," Mr. Kucinich said.
Gee, ya think?